Date of sending : 2017.04.21 Filename: NKFX00KVC020000EU408(V1.01_E2F4).bin Rom-ID : NKFX00KVC020000EU408(V1.01_E2F4) Type : NE77 + Optic AntiFish System(Control) : NKFX00K Device(Protocol): VC02 ( Pulse+JCM Parallel+ID003) Judgement(Notes): EU408 Checksum : E2F4 Currency : EUR Accepted notes : 5(Old 2002ĦBNew2013)ĦA10(Old 2002ĦBNew2014)ĦA20(Old 2002ĦBNew2015)ĦA50(Old 2002, new 2017) 4 bills Accepted ways : 4 Dip switch settings: --------------------------------------------- 10 ON: Pulse Procotol *OFF: Other Procotol --------------------------------------------- ==================================================================================== ID003 dip switch settings ==================================================================================== Dip switch settings: ------------------------------------------------------------------------------------ 1 ON: Reserve * OFF: Reserve ------------------------------------------------------------------------------------ 2 * ON: ID003 Potocol OFF: JCM Parallel Potocol ------------------------------------------------------------------------------------ 3 ON: Reserve * OFF: Reserve ------------------------------------------------------------------------------------ * ON: Enable Output Sensor Detect 4 OFF: Disable Output Sensor Detect ------------------------------------------------------------------------------------ 5 ON: Reserve * OFF: Reserve ------------------------------------------------------------------------------------ 6 ON: Optical anti-fishing malfunction , BA will be still in working order * OFF: BA will stop to work when it acknowledges Optical anti-fishing malfunction ------------------------------------------------------------------------------------ 7 OFF * OFF ON ON 8 OFF * ON OFF ON EUR 5 -- EUR 5 EUR 5 EUR 10 EUR 10 EUR 10 EUR 10 -- EUR 20 EUR 20 EUR 20 -- EUR 50 -- EUR 50 ------------------------------------------------------------------------------------ 9 ON : Disable Bill Reject 4 Times BA Stop By 30 Sec * OFF: Enable Bill Reject 4 Times BA Stop By 30 Sec ------------------------------------------------------------------------------------ ===================================================================================== Pulse dip switch settings ===================================================================================== 1 ON: 5 Euro = 5 pulses * OFF: 5 Euro = 1 pulses ------------------------------------------------------------------------------------- 2 * OFF OFF ON ON 3 * OFF ON OFF ON 150/180ms 50/50ms 80/120ms 50/300ms ------------------------------------------------------------------------------------- 4 * ON: Enable Output Sensor Detect OFF: Disable Output Sensor Detect ------------------------------------------------------------------------------------- 5 ON: Inhibit level Active High * OFF: Inhibit level Active Low ------------------------------------------------------------------------------------- 6 ON: Optical anti-fishing malfunction , BA will be still in working order * OFF: BA will stop to work when it acknowledges Optical anti-fishing malfunction ------------------------------------------------------------------------------------- 7 OFF * OFF ON ON 8 OFF * ON OFF ON EUR 5 -- EUR 5 EUR 5 EUR 10 EUR 10 EUR 10 EUR 10 -- EUR 20 EUR 20 EUR 20 -- EUR 50 -- EUR 50 ------------------------------------------------------------------------------------- 9 ON : Disable Bill Reject 4 Times BA Stop By 30 Sec * OFF: Enable Bill Reject 4 Times BA Stop By 30 Sec ------------------------------------------------------------------------------------- ===================================================================================== JCM Parallel dip switch settings ===================================================================================== ------------------------------------------------------------------------------------- 1 ON: WITH ESCOW FUNCTION * OFF: NO ESCOW FUNCTION ------------------------------------------------------------------------------------- 2 ON: ID003 Potocol * OFF: JCM Parallel Potocol ------------------------------------------------------------------------------------- 3 * ON: Encryption MODE OFF: Decrypt MODE ------------------------------------------------------------------------------------- 4 * ON: Enable Output Sensor Detect OFF: Disable Output Sensor Detect ------------------------------------------------------------------------------------- 5 ON: Reserved * OFF: Reserved ------------------------------------------------------------------------------------- 6 ON: Optical anti-fishing malfunction , BA will be still in working order * OFF: BA will stop to work when it acknowledges Optical anti-fishing malfunction ------------------------------------------------------------------------------------- 7 OFF * OFF ON ON 8 OFF * ON OFF ON EUR 5 -- EUR 5 EUR 5 EUR 10 EUR 10 EUR 10 EUR 10 -- EUR 20 EUR 20 EUR 20 -- EUR 50 -- EUR 50 -------------------------------------------------------------------------------------- 9 ON : Disable Bill Reject 4 Times BA Stop By 30 Sec * OFF: Enable Bill Reject 4 Times BA Stop By 30 Sec -------------------------------------------------------------------------------------- NOTE @ ------ * Manufacture setting ** ON :Autocheck motor reversal OFF:When output or hook is triggered in power on, error message displays three red, until after trouble clearing into autocheck. *** ON :(1)After accepted banknotes through output sensor, if detect output trigger again, display sensor problem. (2)After accepted banknote didn't leave output sensor, display sensor problem. OFF:(1)After accepted banknotes through output sensor, if detect output trigger again, display sensor problem. (2)After accepted banknote didn't leave output sensor, return to the idle. Note: Please restart the bill acceptor after any changes on dip switch(s) has been made. ID003 INFORMATION ==============================|============================== ESCROW DATA |CURRENCY ASSIGN DATA ==============================|============================== Code Denomination |Code Country Denomination Exp. ------------------------------|------------------------------ 61h Reserved |61h E0 00h 00h 62h £á5 |62h E0 05h 00h 63h £á10 |63h E0 0Ah 00h 64h £á20 |64h E0 14h 00h 65h £á50 |65h E0 32h 00h ==============================|==============================